Product Description
In fine chemical processing, additive dosing, and pilot-scale trials, achieving high-precision mass flow measurement of corrosive media in confined spaces is critical for process stability and safety. The COLISEN DN08 ultra-compact U-tube Coriolis mass flow meter - even smaller than micro-bend models - is specifically designed for tight installations, making it an ideal solution for low-flow chemical applications.
Key Challenges & Solutions
1. Installation in Tight Spaces
Challenge: Traditional flow meters are too bulky for compact piping or equipment interiors. Solution: Ultra-compact U-tube design - even smaller than micro-bend tubes - fits easily into restricted areas.
2. High Accuracy at Low Flow
Challenge: Low-flow chemicals (e.g., additives, catalysts) are hard to measure precisely. Solution: Zero stability <0.002 kg/min, maintains 0.15% accuracy down to 20 kg/min.
3. Corrosive Media Compatibility
Challenge: Acids, alkalis, solvents can damage measuring tubes. Solution: Wetted parts in 316L / Hastelloy C, excellent corrosion resistance.
4. Explosion-Proof & Reliability
Challenge: Flammable gases present in chemical plants require high safety ratings. Solution: Ex d ib IIC T6 Gb certified, no moving parts, maintenance-free.
Core Advantages
- Ultra-Compact Size: Even smaller than micro-bend, fits tightest spaces
- Low-Flow Expert: Down to 20kg/min, 0.15% accuracy
- Direct Mass Measurement: Unaffected by temp., pressure, or density changes
- Multi-Parameter Output: Mass flow, density, temperature
- High Corrosion Resistance: 316L / Hastelloy C wetted parts
- Explosion-Proof Certified: Ex d ib IIC T6 Gb
- Maintenance-Free: No moving parts, long service life
- Flexible Connections: Ferrule, thread, compact flange
Typical Applications
- Fine chemical additive dosing
- Catalyst micro-injection
- Solvent transfer & ratio control
- Pilot plant & lab skids
- Corrosive media pipelines
- Reactor feed monitoring
Selection Table
|
Model |
Nominal diameter |
Medium temp. |
Max.W.P |
Max. flow-rate |
||
|
inch |
mm |
kg/min |
Lb/min |
|||
|
CMASS008 |
1/4" |
DN08 |
-50℃~+150℃ |
≤10MPa |
20 |
44 |
|
CMASS015 |
1/2" |
DN15 |
-50℃~+150℃ |
≤8MPa |
60 |
132 |
|
CMASS025 |
1" |
DN25 |
-50℃~+150℃ |
≤8MPa |
200 |
440 |
|
CMASS040 |
1-1/2" |
DN40 |
-50℃~+150℃ |
≤10MPa |
450 |
992 |
|
CMASS050 |
2" |
DN50 |
-50℃~+150℃ |
≤10MPa |
650 |
1433 |